Add to Cart
YQNBT30KW/40KW solar hybrid inverter
Product model:
YQNBT30KW 240V, 40KW/384V,solar hybrid inverter to 110V/220V,built-in 50A /200A PWM charge controller.
Product certificate:
CEIEC
Application area
YQNBT30KW 240V, 40KW/384V,solar hybrid inverter is applicable to large off-grid solar power generation system.Inverter can be used in large communication power station,oil field,drilling operation and other high equipment.
Feature
hybrid inverter solar inverter Parameters
Model:YQNBT | YQNBT30KW | YQNBT40KW | |||||
Rated Power | 30KW | 40KW | |||||
Peak Power(20ms) | 90KW | 120KW | |||||
Start Motor | 15HP | 20HP | |||||
Battery Voltage | 240VDC | 384VDC | |||||
Size(L*W*Hmm) | 720*435*1120 | ||||||
Packing Size(L*W*Hmm) | 790*505*1260(1PCS) | ||||||
N.W.(kg) | 135 | 160 | |||||
G.W.(kg)(Carton Packing) | 150 | 180 | |||||
Installation | Tower | ||||||
Parameter | |||||||
Input | DC Input Voltage Range | 10.5-15VDC(Single battery voltage) | |||||
AC Input Voltage Range | 98VAC~125VAC/195 VAC~250VAC | ||||||
AC Input Frequency Range | 45Hz~65Hz | ||||||
Max AC charging current | 15AMAX(Depending on the model) | ||||||
AC charging voltage | LEAD battery:Charge Voltage:14V;Float Voltage:13.8V(Single battery voltage) | ||||||
AC charging method | Three-stage(constant current,constant voltage,floating charge) | ||||||
| Efficiency(Battery Mode) | ≥85% | |||||
Output Voltage(Battery Mode) | 110VAC±2%/220VAC±2%(Battery Mode) | ||||||
Output Frequency(Battery Mode) | 50Hz±0.5or60Hz±0.5 | ||||||
Output Wave(Battery Mode) | Pure Sine Wave | ||||||
Efficiency(AC Mode) | >99% | ||||||
Output Voltage (AC Mode) | 110VAC±10% / 220VAC±10% | ||||||
Output Frequency (AC Mode) | Tracking Automatically | ||||||
Output waveform distortion(Battery Mode) | ≤3%(Linear load) | ||||||
No load loss(Battery Mode) | ≤1% rated power | ||||||
No load loss(AC Mode) | ≤2% rated power( charger does not work in AC mode) | ||||||
No load loss(Energy saving Mode) | ≤10W | ||||||
Battery Type | Customized battery | Charge and discharge parameters of different types of batteries(such as lithium batteries,etc.)can be customized according to user requirements. | |||||
Battery undervoltage alarm | 11V(Single battery voltage) | ||||||
Battery undervoltage protection | 10.5V(Single battery voltage) | ||||||
Battery overvoltage alarm | 15V(Single battery voltage) | ||||||
Battery overvoltage protection | 17V(Single battery voltage) | ||||||
Protection | Battery overvoltage recovery voltage | 14.5V(Single battery voltage) | |||||
Overload power protection | Automatic protection(battery mode),circuit breaker or insurance(AC mode) | ||||||
Output short circuit protection | Automatic protection(battery mode),circuit breaker or insurance(AC mode) | ||||||
Temperature protection | >90°C(Shut down output) | ||||||
Inside Solar controller | Charging Mode | PWM | |||||
Charging current | 240V /384V system: 50A,100A,150A, 200A | ||||||
PV Input Voltage Range | 240V System:300V-440V;384V system:480V-704V; | ||||||
Max PV Input Voltage(At 25°C) | 240V system:500V;384V system:750V | ||||||
PV Array Maximum Power | 240V system: 14KW, 28KW,21KW*2,28KW*2; 384V system: 22.4KW,44.8KW,33.6KW*2,44.8KW*2 ; | ||||||
Standby loss | ≤3W | ||||||
Maximum conversion efficiency | >95% | ||||||
Alarm | A | Normal working condition,buzzer has no alarm sound | |||||
B | Buzzer sounds 4 times per second when battery failure,voltage abnormality,overload protection | ||||||
C | When the machine is turned on for the first time,the buzzer will prompt 5 when the machine is normal | ||||||
Working Mode | Battery First/AC First/Saving Energy Mode | ||||||
Transfer Time | ≤4ms | ||||||
Display | LCD | ||||||
Thermal method | Cooling fan in intelligent control | ||||||
Communication | RS232(Optional) | ||||||
Operating temperature | -10℃~40℃ | ||||||
Storage temperature | -15℃~60℃ | ||||||
Environment | Noise | ≤55dB | |||||
Elevation | 2000m(more than derating) | ||||||
Humidity | 0~95%( No condensation) | ||||||
Note:All specifications are subject to charge without prior notice |