Add to Cart
Product Name: solar PV 3 phase inverter 30KVA-80KVA DC192V/384V invert to AC380V/400V
Product certificate:
CEIECTLC
Application area
Solar PV 3 phase inverter can be used in water pump,bench drill and other industrial electric with high –power thre-phase industrial motorand with total power not exceeding 24KW, 32KW,40KW or 64KW.
Product Description
Feature
Solar Three Phase Power Inverter Parameters
| Model:YQHDSX | 30KVA | 40KVA | 50KVA | 60KVA | 80KVA | |||
| Rated Power | 24KW | 32KW | 40KW | 48KW | 64KW | |||
| Battery Voltage | 192V/384VDC | 384VDC | ||||||
| Size(L*W*Hmm) | 715*575*1275 | |||||||
| Packing Size(L*W*Hmm) | 775*635*1400 | |||||||
| N.W.(kg) | 174 | 202 | 297 | 326 | 398 | |||
| G.W.(kg)(Wooden Packing) | 198 | 226 | 321 | 350 | 422 | |||
| Parameter | ||||||||
| Input | AC Input Voltage Range | 380VAC/400VAC±10%(customized 190VAC/200VAC) | ||||||
| AC Input Frequency Range | 45Hz~65Hz | |||||||
| Phase | 3/N/PE | |||||||
|
Output |
Efficiency | ≥85% | ||||||
| Output Voltage(Battery Mode) | 380VAC/400VAC±10%(Customized 190VAC/200VAC) | |||||||
| Output Frequency(Battery Mode) | 50/60Hz ±1% | |||||||
| Output Wave (Battery Mode) | Pure Sine Wave | |||||||
| THD | Liner load≤3% | |||||||
| AC Output Voltage Range | Conforming to A C input | |||||||
| AC Output Frequency Range | Conforming to A C input | |||||||
| Phase | 3/N/PE | |||||||
|
Battery |
DC input voltage range | 10.5-17V DC/Single battery | ||||||
| Battery low voltage alarm | 11V /Single battery | |||||||
| Battery low voltage protection | 10.5V DC/Single battery | |||||||
| Battery high voltage alarm | 15V /Single battery | |||||||
| Battery high voltage protection | 17V DC/Single battery | |||||||
| Battery Type | U0: Gel U.S.A / U1: A.G.M.1 /U2: A.G.M.2 / U3: Sealed lead Acid / U4: Gel European / U5: Open lead Acid / U6: Calcuim(open) / U7: Sulphation cycle | |||||||
| Working Mode | Battery First/AC First/Saving Energy Mode | |||||||
| Transfer Time | ≤4ms | |||||||
| AC Charging current(selectable) | 0~45A | |||||||
| Display | LCD | |||||||
| Thermal method | Forced air cooling | |||||||
| Protection | Over-load/Over-discharge/Short circuit/High and low temperature | |||||||
| Communication | RS232/RS485/APP/SNMP/GSM(Optional) | |||||||
| Enviroment | Noise | ≤65dB | ||||||
| Temperature | -10℃~40℃ | |||||||
| Humidity | 0~95%( No condensation) | |||||||
| Height | 2000m(Less load when height over) | |||||||
| Note:All specifications are subject to charge without prior notice | ||||||||